On Tue, 17 Jul 2001 08:11:58 -0400 Austin Franklin
(darkroom@ix.netcom.com) wrote:
> Many
> scanner documents have used the term DMax interchangeably with dynamic
> range.
They are wrong to do so :)
DMax is a measure of the minimum transmissive opacity of a film. DMin is a
measure of the maximum transmissive opacity. Dynamic range is DMax-DMin.
Pretending DMin=0 is of course beneficial for marketing purposes ;)
Regards
Tony Sleep
http://www.halftone.co.uk - Online portfolio & exhibit; + film scanner info