Filmscanners mailing list archive (filmscanners@halftone.co.uk)
[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[filmscanners] Re: Sprintscan 4000 does not initialize anymore
markup
To: lexa@lexa.ru
Subject: [filmscanners] Re: Sprintscan 4000 does not initialize anymore
From: "Tony Sleep" <tonysleep@halftone.co.uk>
Date: Thu, 17 Sep 2009 14:31:28 +0100
In-reply-to: <OFAA61F3A3.B4B605D5-ONC125761D.001F892D-C125761D.002334D5@deutsche-boerse.com>
List-archive: <http://www.mail-archive.com/filmscanners@halftone.co.uk>
List-post: <mailto:filmscanners@halftone.co.uk> (No HTML, plain text only)
List-subscribe: <mailto:listserver@halftone.co.uk> (use 'Subscribe filmscanners@halftone.co.uk')
List-unsubscribe: <mailto:listserver@halftone.co.uk> (use 'Unsubscribe filmscanners@halftone.co.uk')
Organization: Tony Sleep Photography
References: <OFAA61F3A3.B4B605D5-ONC125761D.001F892D-C125761D.002334D5@deutsche-boerse.com>
On 25/08/2009 Barbara.Nitz@deutsche-boerse.com wrote:
> Has anyone seen this, too, and found a way to fix it? There isn't any
> Polaroid support in Germany anymore as far as I can see, I don't have
> the
> dust brush (which was used when the scanner did not STOP blinking,
> anyway),
> I am reluctant to do anything to the 'innards' of the scanner just
> yet, and
> I hope for a miracle. :-)
Sorry for the slow response.
I'd hazard a guess that in 3 or so years of disuse, either lubricant on
the carriage mechanism has dried out so the scanner motors are unable to
rack the carriage through initialisation, or you have a poor plug connection.
I will be putting up a page about DIY servicing of the '4000 ASAP which
may help. I didn't plan to, but mine just threw a wobbly right when I was
on deadline to scan some 1983 negs, and I *had* to fix it, and this time
took a few photos whilst it was apart.
--
Regards
Tony Sleep
http://tonysleep.co.uk
----------------------------------------------------------------------------------------