Hello!
Пытаюсь подключить 5350 PRI-ем к Meridian-у:
isdn switch-type primary-net5
controller E1 3/0
framing NO-CRC4
pri-group timeslots 1-31
Контроллер подымается:
E1 3/0 is up.
Applique type is Channelized E1 - balanced
No alarms detected.
alarm-trigger is not set
Version info of slot 3: HW: 256, PLD Rev: 1
Framer Version: 0x8
sh isdn status показывает:
Global ISDN Switchtype = primary-net5
ISDN Serial3/0:15 interface
dsl 0, interface ISDN Switchtype = primary-net5
Layer 1 Status:
ACTIVE
Layer 2 Status:
TEI = 0, Ces = 1, SAPI = 0, State = TEI_ASSIGNED
Layer 3 Status:
0 Active Layer 3 Call(s)
Active dsl 0 CCBs = 0
The Free Channel Mask: 0xFFFF7FFF
Number of L2 Discards = 0, L2 Session ID = 2
Total Allocated ISDN CCBs = 0
debug isdn q921 радостно сообщает:
Jun 19 18:49:55: ISDN Se3/0:15: RX <- BAD FRAME(0x00017F)Line may be looped!
Jun 19 18:49:57: ISDN Se3/0:15: RX <- BAD FRAME(0x00017F)Line may be looped!
Jun 19 18:49:58: ISDN Se3/0:15: RX <- BAD FRAME(0x00017F)Line may be looped!
Jun 19 18:50:00: ISDN Se3/0:15: RX <- BAD FRAME(0x00017F)Line may be looped!
В чем могут быть грабли? Подозреваю, что проблема со стороны Meridian-а,
может кто присоветует что и как там глянуть?
--
Regards,
Vladimir.
=============================================================================